Description: Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 °C to + 50 °C Storage Temperature -40 °C to + 60 °C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 DC volts Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) AC volts1 true-rms Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) Continuity Range: 600 Ω Resolution: 1 Ω Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. Ohms Range/Resolution: 600.0 Ω / 0.1 Ω Range/Resolution: 6.000 kΩ / 0.001 kΩ Range/Resolution: 60.00 kΩ / 0.01 kΩ Range/Resolution: 600.0 kΩ / 0.1 kΩ Range/Resolution: 6.000 MΩ / 0.001 MΩ Accuracy: 0.9 % + 1 Range/Resolution: 40.00 MΩ / 0.01 MΩ Accuracy: 5 % + 2 Diode Test Range/Resolution: 2.00 V / 0.001 V Accuracy: 0.9% + 2 Capacitance Range/Resolution: 1000 nF / 1 nF Range/Resolution: 10.00 µF / 0.01 µF Range/Resolution: 100.0 µF / 0.1 µF Range/Resolution: 9999 µF / 1 µF Range/Resolution: 100 µF to 1000 µF Accuracy: 1.9% + 2 Range/Resolution: > 1000 µF Accuracy: 5% + 20% Lo-Z Capacitance Range: 1 nF to 500 µF Accuracy: 10% + 2 typical AC amps true-rms (45 Hz to 500Hz) Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.5% + 3 20 A overload for 30-seconds max DC amps Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.0% + 3 20 A overload for 30-seconds max Hz (V or A input)2 Range/Resolution: 99.99 Hz / 0.01 Hz Range/Resolution: 999.9 Hz / 0.01 Hz Range/Resolution: 9.999 kHz / 0.001 kHz Range/Resolution: 50 kHz / 0.01 kHz Accuracy: 0.1% + 2 Notes: 1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F 2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage Mechanical & General Specifications Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") Weight 550 g Package Includes: 1. FLUKE 115C Digital Multimeter; 2. Fluke Test lead; 3. Operation manual in English; 4. Battery
Price: 229.99 USD
Location: Union City, California
End Time: 2024-10-26T04:23:27.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Fluke
UPC: Does not apply
MPN: Do not apply
Features: Backlight